Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix
Peri-Strips Dry Staple Line Reinforcement with Veritas (PSDV) Collagen Matrix is designed to help surgeons improve outcomes and enable patient healing in bariatric, gastric, lung* and small bowel procedures. By delivering a naturally strong and biocompatible material, Peri-Strips Dry with Veritas has been shown to reduce the risk of leaks and bleeds along the staple line.1

Explore this Product
Overview
The Simplicity of PSDV Staple Line Reinforcement Now With Secure Grip Technology
Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix comes with Secure Grip Technology, arming you with the power of a biologic material you can rely on combined with the convenience of a faster, simpler preparation.2,3

Advantages of Peri-Strips Dry Staple Line Reinforcement with Secure Grip Technology
Faster Preparation Time
PSDV Secure Grip resulted in a 54.55% reduction in preparation time when compared to Gore Seamguard and a 59.67% reduction in preparation time when compared to PSDV Gel.2

Easiest to Prepare, Easiest to Learn2
A straightforward, intuitive preparation that’s easy to adopt.
Reduces the risk of error2
Easy for new users to adopt2
In a preclinical study, participants rated PSDV Secure Grip easier to learn than Gore Seamguard and PSDV Gel.2

Strong From the Start
Burst Strength**
A preclinical study evaluating staple line seam integrity at intraluminal pressures in the immediate postoperative period with a canine model demonstrated that:
- Regardless of the operative techniques, the buttressed ileocolic anastomoses showed higher bursting pressures.**7
- Buttressed anastomoses never ruptured at the staple line.**7

Confidence at the Staple Line
Over 15 years and two million implants, Peri-Strips Dry with Veritas has been proven to improve clinical outcomes and reduce procedural complications.1,4,9

The Staple Line Reinforcement Most Preferred by OR Nurses and Scrub Technicians
30 out of 30 nurses and scrub technicians ranked PSDV Secure Grip the #1 preferred staple line reinforcement.2
Additional Peri-Strips Benefits
Outperforms Synthetic PGA Material
Peri-Strips Dry with Veritas is derived from bovine pericardium and outperforms synthetic PGA material at the staple line over time in sleeve gastrectomy/gastric bypass patients.4
Reduced Risk of Staple Line Leaks and Bleeds
In a multicenter comparative use study, Peri-Strips Dry with Veritas significantly lowered the risk of postoperative bleeding and leaks at the staple line compared to competitive products, over-sewing and no staple line reinforcement.1
Remodeling Characteristics Support Wound Healing
Peri-Strips Dry with Veritas provides structural integrity that supports the host tissue’s formation of new collagen.5 Upon implantation, PSDV acts as a scaffold for extracellular matrix (ECM) deposition and will degrade during the remodeling phase of tissue healing.**,6
Features
Simple “Peel ‘N’ Secure” Preparation
The Secure Grip technology consists of a pressure-sensitive adhesive that provides optimal adherence and release of the buttress from the stapler, facilitating easy manipulation of tissue.8

Order & Support
Learn More About Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix
Ordering and Support Information for Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix
Get additional ordering, customer, technical, and medical support information for Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix by contacting Baxter using the links below.

U.S. Catalog
To buy this product, purchase OEM parts and accessories, or look for options and specs please visit U.S. Catalog.

U.S. Support
For manuals and documentation, product training, technical support and services, submit repair and return requests or check order status for Hillrom, Allen Medical and Welch Allyn product please visit U.S. Support.

U.S. Edu
For medical information or non-promotional education about our products or therapies, please visit U.S. Edu.

Contact Us
To find contact details and assistance for Baxter products, report an adverse event or report a product complaint, or any other inquiries, please visit our contact us page.
Are You Interested in Additional Information About Peri-Strips?
Resources
Resources for Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix
More Products
Other Information
Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix Indications and Important Risk Information
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Indications
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Reinforcement is intended for use as a prosthesis for the surgical repair of soft tissue deficiencies using surgical staplers when staple line reinforcement is needed.
(Secure Grip only) PSDV-SG is intended for use as a prosthesis for the surgical repair of soft tissue deficiencies using surgical staplers when staple line reinforcement is needed. PSDV-SG can be used for reinforcement of staple lines during bariatric, gastric, small bowel, colon, and colorectal procedures.
(Circular Reinforcement only) PSDV reinforcement can be used for reinforcement of staple lines during gastric, bariatric, and small bowel procedures.
(Linear Reinforcement only) PSDV Reinforcement can be used for reinforcement of staple lines during lung and bronchus resections and during bariatric surgical procedures, and during gastric, small bowel, mesentery, colon, and colorectal procedures.
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Important Risk Information
The use of PSDV-SG is contraindicated in patients with known sensitivity to bovine or acrylic material(s).
Do not re-sterilize. Resterilization may cause changes to the tissue and negatively impact functionality of the device.
Discard all open, used, or unused components as sterility is no longer assured.
Do not use product if there is damage to the pouch or seals as sterility may be compromised.
Ensure the staple line is completely covered with the buttress, or it may result in inadequate coverage after firing.
PSDV-SG is not designed, sold, or intended for use except as indicated; doing so may result in surgical complications.
PSDV-SG configurations differ; substitution of one product for another product may reduce product performance.
Do not use PSDV-SG if the product has been submerged in liquids or if heat indicator has been activated.
Use care when removing loading unit components from the stapler to prevent buttress dislodgement.
Do not get the anvil or cartridge buttress wet before applying, or the buttress may not adhere to the stapler properly.
Ensure the anvil and cartridge side of the loading unit are on the corresponding stapler jaws or the buttress may not adhere to the stapler properly.
Final tissue compression, including PSDV-SG, must meet the range specified by the stapler manufacturer; this is especially important if staple firings are overlapped. PSDV-SG increases the total thickness of the area stapled by 0.45 mm–0.86 mm (0.018"–0.033").
Follow Instructions for Use supplied by the stapler manufacturer. Do not use PSDV-SG contrary to the stapler manufacturer’s instructions.
The cartridge and anvil sides of the PSDV-SG loading unit differ; substitution of one side for the other may interfere with alignment and adherence of the buttress strips.
The use of PSDV-SG has not been studied in lung or bronchus resection.
PSDV FULL INSTRUCTIONS FOR USE
Disclaimers
*PSDV Secure Grip is not approved for lung.
**Preclinical data results may not correlate to results in humans.
Rx only. For safe and proper use of product mentioned herein, please refer to the Operator’s Manual or Instructions for Use.
Baxter, Coseal, Floseal, Peri-Strips, Secure Grip and Veritas are trademarks of Baxter International Inc. or its subsidiaries.
Gore Seamguard is a trademark of Gore Medical or its subsidiaries.
Any other trademarks, product names or brand images are the property of their respective owners.
References
- D’Ugo S, Gentileschi P, Benavoli D, et al. Comparative use of different techniques for leaks and bleeding prevention during laporoscopic sleeve gastrectomy: a multicenter study. Surg Obes Relat Dis. 2013 Nov 12.[Epub ahead of print].
- Baxter Data on File. REF-26181
- PSDV Secure Grip Instructions for Use 2020. IFU-0068
- Shikora Scott A., Kim Julie J., Tarnoff Michael E. Comparison of Permanent and Non-Permanent Staple Line Buttressing Materials For Linear Gastric Staple Lines During Laparoscopic Roux-en-Y Gastric Bypass 2008;4:729-734.3.
- Oray BN, Kelly S, Konobeck T, Lamber A, Mooradian DL. Novel Propylene Oxide-Treaded Bovine Pericardium as a Soft Tissue Repair Material and Potential Scaffold for Tissue Engineering, Surgical Technology International XVIII.
- Deeken C, Melman L, Jenkins E, Greco S, Frisella M; Matthews B; Histologic and biomechanical evaluation of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral incisional hernia repair. J Am Coll Surg. 2011;212(5):880-888.
- Gaertner WB, Hagerman GF, Potter MJ, Karulf RE. Experimental evaluation of a bovine pericardium-derived collagen matrix buttress in ileocolic and colon anastomoses. J Biomed Mater Res B Appl Biomater. 2010;92(1):48-54.
- Baxter Data on File. REF-33159
- Data on file. AS-0012R. Synovis Surgical Innovations

